Комментарии:
Nice set up. How would you connect a 13k generator to this set up?
ОтветитьHow do you connect the solar charge controller in a spliphase setup with 2 Inverters ?
ОтветитьYes, I agree... One unit with split phase 120v & 240v would be the one to go. Great video. Thank you!
ОтветитьProlly easier to pull the wire with a fish tape before you fasten the conduit to the inverter.
ОтветитьHi Will. With regards to the Victron 48V Quattro 15kVA 277V Inverter 200A Charger, I will need a charge controller I am assuming. What else would be required to make it ready for operation? PV panels, pv wiring, not to be cosidered as yet. Assume that the current/voltage from the pv, satisifies the requirements in the Quattro 15KVA spreadsheet.
ОтветитьThanks Will for the video. I'm using 2 12v/ 3000 watt multiplus II for my boat which has 2 30amp shore power legs. I'm still working out the details of integrating the 7k generator and distribution of the AC loads on the boat. My main reasoning is capacity, but more importantly is redundant systems.
ОтветитьTHERE IS MULTIPLUS ii THAT HAVE CERBO GX INTEGRATED [MULTIPLUS II GX], JUST US DONT IMPORT IT. ALSO IT IS ONLY LITTLE BIT HIGHER IN PRICE THAN REGULAR MULTIPLUS II.
ОтветитьI just got a email and a credit for $50 and 2 year warranty extension
ОтветитьWAT??? 2 IN PARALEL TO HAVE 240 ?? WAY NOT 1 ITS NAW VICTRON 1 PACE CHEND TRASFORM 120. IN 2040 U DONT NID 2 OF DIS LIKE YOU TELL U MEC RECLAM BUT PEOPLE DE ARE NOT STUPID DE ARE BETER DEN YOU MENY PEOPLE HWO INVERT SOLAR ETC YOU LITEL TO MUCH SPHIHO DRAMA ON LITION 4OP
ОтветитьWhen pushing your wire thru any flexible conduit, take a loop of one of the wires (at the push end) double it back, in a tight loop and then tape the other wires below the loop. It will push so much easier and almost never hang up in the flex at the end or anywhere else.
Ответитьnot good
ОтветитьCan tgis be done with the 12v Dc models?
ОтветитьI have 2 identical 120v single phase power stations with 30 amp connectors (24 amps max), can I use them with these inverters to give 240v split phase so I can power 2 legs of a sub panel?
ОтветитьI appreciate if you could do a video showing how to connect 2 victron multiple plus2 inverter in parallel
ОтветитьThere IS an all-in-one unit that includes a pretty good MPPT AND the Cerbo GX, and it's the Easysolar.
ОтветитьIs there a victron all in one
ОтветитьDoes anybody in here knows somebody in south jersey that knows how to set a solar system? I have a fifth wheel and somebody attemp to installed mine and I know it's not working properly. Help! Please
ОтветитьSomeone may have posted this, but 2300 watts is not far off their rated spec of 2400W continious. I still don't get why they call it 3KVA when it can only do 2400-watts continous.
ОтветитьDo you have a video of a victron 240v grid tied solar with battery and gas generator backup?
ОтветитьIf you do not need the higher amperage, you could also use one of the Victron Autotransformers and not get a second MultiPlus for the second leg of the split-phase system.
ОтветитьOk I have a multi plus II 24v 3000 I am off grid have been for past 6 months and yes I find the over load comes on 2300 watts I am very happy with my system it works well and I've been considering adding a second victron 24 volt 3000 to the system just to help if I'm running the coffee pot and the air conditioner mini split heat pump the same time the fridge kicks in I can se😮e how this would be an answer my concerns are if I get another unit can I get the information to program it and second sometimes when we don't get enough Sun I will run a generator if I plug in the generator in with a 30 amp twist to the victron my generator does have 240 would I be better off running the through the box at 240 to feed each inverter. This is just a thought at this point but down the line it's something I seriously consider I can live quite comfortably on 350kwh a month great video thank you and if anybody knows where I can find out more information please point me in that direction
ОтветитьHey Will, Can you demonstrate Enphase AC coupling with these units?
ОтветитьI think you made a mistake on wiring. The Vic manual calls for 3 strand 6ga AC-in, 6ga AC-1 out, 10ga AC-2 out. I think you ran 10ga solid on AC1 out. That might be why the Tesla could only charge at a lower amps, the wires got hot and had resistance? Am I wrong? Maybe its different for dual phase?? The vic 3000 can pump out 75a on boost to AC1 and AC2 outs. Also the manual says to use 3 strand not solid wire.
ОтветитьI try to follow along but it is difficult having no experience/ knowledge. Anyway, I’m assuming that utilizing the multiplus 2 for a split phase 120V/240V output, what you are talking about is a higher output for faster charging like for a Tesla?
ОтветитьIts manual states exactly 2400 Watts maximal so why are you surprised?
ОтветитьThose exposed bus bars on the wall make me nervous
ОтветитьHey Will, I had pretty good luck with Calpha. 5kw parallel inverter
ОтветитьCurious, why use the resistor to “charge”
The capacitors instead of just connecting ? Is the spark bad for the unit?
so, with just 20 A, that is not going to allow you to have your gaming computer, HVAC unit, induction cooktop, or microwave running at the same time?
ОтветитьHow much is this system???
ОтветитьThanks!
Ответитьhey @WillProwse do you have any reviews or experience with the Victron Energy Quattro 5000VA 48 or Victron Quattro 48/10000/140-100/100-230V - +50A Aux VE.Bus. I currently have 2 of multiplus II 3000 iin different configs but I need to run some larger 240v things and it looks like the standalone quattro can do this.
Ответитьisn't black normally negative especially not hot im a aussie also
ОтветитьThat was a nono, coiling a low voltage data cable around a high voltage power line! Induction is not your friend here.
ОтветитьNeed to remove all the other grounds from the neutral bar if your separating them. :)
ОтветитьOh, and thanks Will, love your videos buddy, I’ve learned a ton from them!
ОтветитьWould much rather spend a few extra bucks up front for a system i dont have to worry about then buy more cheap Amazoneze crap!
ОтветитьCan you connect a 48v quatro with a multiplus two to get 240?
Or do they both need to be like inverters?
what is your battery bank configured for to feed the inverters 12v, 24v, 48v ??
ОтветитьCan I parallel two of the same PowMr inverters @ 110v each and get 220v single phase? If so, then would I tie the two neutrals together?
Thanks.
You can buy the Multi RS Solar which is a complete home energy storage system in one box
ОтветитьI wanted to do a full victron system before I saw the total. Just not for me. Cool products, I would even consider using one of the Phoenix inverters for my well and septic pumps.
ОтветитьMy Multiplus-II, with minimal torque on the battery terminal, it sheared off and inside was powdered metal with the outside tinned. Thought the battery terminal would be stainless steel but it isn't. They fixed it under warranty but it cost me $100 to ship it to the repair center. Have the new one installed but not powered on fully yet. Still have some wiring to do.
ОтветитьHow many volts of solar to connect to solar panels?
Ответитьwhat are the resistor specs?
ОтветитьGreat Video!.
When will the Victron 20KVA system be available?
Dear mr. Prowse, I found this Victron Multiplus 2 which does split phase 2 * 120V 3 kVA. Would that solve the connection problem for your 2 5kVA units? Datasheet-MultiPlus-II-3kVA-2x120V-EN-
ОтветитьThank you very much for your clear explanation. I intend to copy this system in my house in Davao, Philippines.
Ответить