Комментарии:
Thanks for the video , I have a 24V DC versoin and I am trying to get a 24 volt DC water heater working through one of these and I can set it up , get the power to come on , runs through the P1-5 on / off programme ( on for 5 seconds off for 15 ) but it doesn't put out any power whatsoever , any ideas, I was wondering if the 300watt dump load is too powerful.
ОтветитьHow to set 0.1 second?
Ответитьshow us how to program it to switch n after two and half hours. please
ОтветитьHi, where to purchase,,,these timers in india...
ОтветитьHi I have one exactly the same do I have to only use Dc Power or I can connect on AC , thanks
ОтветитьThanks for that
Ответитьhi there , thank you for your demostration. does the P1 -4 can you set the time in minutes instead of seconds? thank you sir
ОтветитьWill the timer start when power is applied? For instance, in case of power loss, will the timer start when power is restored? Or do you need to press a button to start the timer after power loss.
ОтветитьIf I want to set it to be cycling
( OFF for 2 hours and ON for 15 sec.) and repeat itself
Bunun Türkçe anlatımı yok mu ?
ОтветитьThanks a lot for this vedio. I have a need to light a bulb in case my water pump is running more than a specified time (more than 30mins). Can that be done with this ?
ОтветитьThank you! Very useful
ОтветитьSir pls give the link for buy this product
ОтветитьSo this relay does not deliver any power from the power supply but only serves to complete a circuit? The 12 volts is only for powering up the module then? Other than the power required, what difference would the 24v have from the 12v?
ОтветитьThe title says "... 0.1s- ...". This is not true, because the timer does not support measurements of less than one second.
ОтветитьThanks for the video. Rally appreciate it.
ОтветитьWhat is the maximum output of it?
ОтветитьNow can you set your on time for 30 seconds and off for 6 hours or does the on off have to be in the same time setting as in the on and off both have to be in seconds,min, or hours. I need mine on 30 sec off 6 hours
ОтветитьVery good one. Already to using this
ОтветитьWhat happens if the power goes off.
The timer save the last program or not
HOW TO SE T 3 HRS OFF AND 6 SEC ON? CNAT FIND IN THE VIDEO
Ответитьhello hi, what if im not using the powerload at S1 and S0 ? can i connect the Life wire with S1 and Neutral wire with S0 and by using the T wire connection to the load
ОтветитьHello Mr. Shamshiri,
please, is it capable multiple different commands in a one line? e.g.:
5sec on - 30sec off - 1min on - 30min off - 1hour on - 3hour off...
Thanks.
12 hrs on, 12hrs off :)
ОтветитьHello
Thanks for the video.
Can you help me on the following:
I have 2 Air-conditioning units which I don't want to have them turn on (takeoff) at the same time as if that happens the main circuit breaker switch trips.
Therefore I need some sort of a delay-On device that receives signals from the two thermostats of the two AC units and then pass them to there assigned magnetic contactors one after the other with a time difference between the two to prevent the units from turning on at the same moment which will lead to MCB tripping.
Waiting for your valuable answer.
Regards,
Can this module be programmed to simply shut off the load after 3hrs?
Thank you .
Sir how to put decimal point to the timer?
ОтветитьCan ypu show me the setting of t1 is seconds and t2 is hours
ОтветитьWa'alaikum salam... Brother... I am from Indonesia.... GBU....
ОтветитьThank you for this video. Now I can use it ☺️
Ответить2 things I noticed in this video, 1) the light came on before you even hooked up the wire and 2) there's no way the light would have worked the way you hooked it up (the hot wire coming from the timer can't be hooked to the negative of the bulb because that's reversing polarity and it won't work that way). However the wiring for the timer is correct it just wouldn't work the way you had the bulb hooked up
Ответитьsir give me a schematic diagram more power thank you
ОтветитьI suspect PV = Primary Value, SV = Secondary Value
ОтветитьIs there any way to Fix the T2 time - so that it is always limited for safety ? Or to remove options? Can this be done using Tx and Rx on the rear ? Could you make a video describing how ?
ОтветитьGood evening, I wanted help setting the parameters. I should set the timer for 7 hours and I would like every 20 seconds to work and 20 seconds not. My device controls a sardine mincer for tuna groundbait. How should I set it? Thank you so much for your help and for your kindness.
ОтветитьI only connected the power supply, a button to turn it on and off and a speed regulator even if it runs very slowly because I need more power than speed given by the characteristics of the motor. It's correct? Thank you
ОтветитьI want the timer to have a default setting of 4 second delay then turn on for a long time say 8 hours - I don't need more than one setting - So if I switch the 12 volt power on and off (key switch) then what will be the default setting? Does my question make sense
ОтветитьThanks for the video. I was curious if this has dual polarity like a normal relay? I'm trying to set a motor to auto reverse at a specific time interval. Would I need to use a normal relay in conjunction with this device in order to achieve the outcome?
ОтветитьThe module can be triggered remotey, for example with a sensor?
ОтветитьThe timer is .1 second minimum not 1 second. Is this an error? The advertisement for these say .1 second. This is important if used as a spot welder controller
ОтветитьPv & Sv usually used in controllers like temperature controllers. Pv = Process Value (for example temperature measured in the oven). Sv = Set Value (target temperature for the oven).
ОтветитьCan this device memorize the program?
ОтветитьCan anybody give me the settings for this scenario? I want to switch on my 12V DC water motor .. 1 hr per day only. i.e. using this timer my 12V dc motor will run automatically for 1 hour per day . And this has to reoeat everyday
ОтветитьHola me puede decir como hago para que encienda cada 8horas y trabeje por 8 0 10 segundos ??
ОтветитьHello sir, can this timer controller set for 24 hour
ОтветитьRobojax.. how robust do you consider this unit?
I am planning to use this in an offroad vehicle. Is there a way you could suggest to help it be more robust? Example in combat robots, RC applications and similar devices they have sorta homebrewed potted similar electronic devices... Filling the whole inside with Hotglue. Some have spraying insides with various mixtures of homebrewed silicon mixtures etc.
sadly looks like not going to get a reply. will try anyway. what do you call the pin thingy added to these wires to plug into each of the four spots? coming off the bottom is NOT going to work for my set up. Anyone got an idea on how to turn wire input 90 degrees to point backward instead of straight down or other configurations? any kind of adapters you can plug into this screw type terminal block? Are the block sizes denoted by color. I see some are green. some are blue. etc. ???
ОтветитьPV means present value
SV means set value
Thank you
Ответить