#diy_solar #diy #do_it_yourself #solar #solar_power #off_grid_solar #ground_mount #ground_mount_rack #ground_mount_solar #off_grid_solar_rack #diy_solar_rack #mobile_rack #portable_rack #wiring #how_to_wire_solar #wiring_solar #solar_wiring #ground_mount_enclosure #ground_enclosure #battery_enclosure #electronics_enclosure #diy_enclosure #diy_solar_enclosureКомментарии:
You could always put a couple DC fans at the top of your power shed to move air in and out. One pulling air in, one pushing air out. They shouldn't pull much power and they could run right off your battery.
ОтветитьAHH the little things that make o4reak a system.
I think the settings are a little cautious, I just paused to read through the settings.
The lvco can be 24v.
Float 27.6
Bulk 28.8
Eq 29.2
I float mine at 26.7v. and bulk at 28.2 depending what I will be doing I may charge higher.
It's a good idea to charge to 29.2 or higher to get to a ovp. As long as you have a low current>5. This will work the battery balance function and give full capacity.
You should not have to do it often, but depends on the cycle depth to how you have to balance and when you add extra battery packs.
Remember lower charge current will extend the battery life, and you also have to deal with cold charging.
I didn't quite get the breaker issue you were having, I see there's cheap ones which you have one on the sdi still, they cannot take the rated power or run under load as they heat up and have high resistance.
Have a look for chint breakers.
When sizing go for the max surge, if you want to keep going, and then have your max expectations lower down the line.
This way you will have a closer trip for faults, and system protection, like two layers of protection.
24v systems tend to draw a fair current, 48, can be nicer. The whole system works differently and more effectively with amps from the array.
you wont be unhappy wirh magnum they go through hell and keep going
ОтветитьMy friend the triangle screen is too large. Must be smaller like used on a screen door. You do not want wasp building nest inside. Looking much better
ОтветитьThat's awesome! No generator overnight anymore hopefully!
ОтветитьExcellent
ОтветитьSTAY COOL
Ответитьthanks fo sharing
ОтветитьL I K E 👍👍👍👍👍 ❤ 🧡💛🧡❤ 💯❣💯❣💯
ОтветитьGlad to see its ironed out
ОтветитьThank you for answering some of my questions! Great job!❤❤
Ответить